1. MAIN ALARM PANEL
1-11
4. To close the [Active Alert] list and [Alert Log], press the MENU/ESC key.
Note 1: The [Alert Log] and [Active Alert] list are not available when there is a BNWAS
alert active. If a BNWAS alert is activated while the [Alert Log] or [Active Alert] list are
open, the menu is closed and the BNWAS display is restored.
Note 2: The help area at the bottom of the [Active Alert] list and [Alert Log] displays
the highest priority alert (currently active alert). If there is no active alert, this area
displays operational guidance.
1.9.3 Operational event indications
When an operational event occurs, the Main Alarm Panel shows the related message
in red, yellow or white in the help area.
* RESET key not pressed or equipment on bridge is not operated.
Indication Event Color
MANUAL OFF Manual Off mode selected. White
Autopilot OFF Auto mode selected, Autopilot signal
off.
White
PREWARNING WATCH ALARM
Push any key.
Presence on bridge* not confirmed
in dormant period.
Yellow
WATCH ALARM (1st Stage) Push
any key.
Presence on bridge* not confirmed
at prewarning phase.
Red
WATCH ALARM (2nd Stage) Push
[RESET] key to stop buzzer.
Presence on bridge* not confirmed
at 1st stage.
Red
WATCH ALARM (3rd Stage) Push
[RESET] key to stop buzzer.
Presence on bridge* not confirmed
at 2nd stage.
Red
WATCH ALARM (2nd Stage: Emer-
gency Call) Push [RESET] key to
stop buzzer.
Emergency call made from Main
Alarm Panel.
Red
WATCH ALARM (3rd Stage: Emer-
gency Call) Push [RESET] key to
stop buzzer.
Emergency call made from Main
Alarm Panel.
Red
2nd Stage: External Emergency Call
Activated
Backup navigator signal received Red
3rd Stage: External Emergency Call
Activated
Backup navigator signal received Red