3. MAINTENANCE, TROUBLESHOOTING
13
3.2 Troubleshooting
The table below provides simple troubleshooting procedures which the user can follow
to restore normal operation. If you cannot restore normal operation, contact your deal-
er for advice.
Trouble Remedy
The display shows “No radar” and radar does not
go into stand-by.
Check if power is being supplied to the antenna
unit.
Check if the power supply is the rated voltage
of the device (12/24 VDC)
Check if the fuse (in the cable assy.) has
blown.
Check all cables for damage.
Check that the software version of the display
unit is compatible with the antenna unit.
The equipment goes into stand-by after start up.
However, no radar echoes appear after transmit-
ting. Then, radar echoes disappear and the mes-
sage "No radar" appears.
Check the power supply voltage and capacity.
Check that all cables are securely connected.
Check all cables for damage.
In TX state, no echoes appear or echoes are
faint.
Check that tuning, gain, sea clutter, and rain clut-
ter are properly adjusted.
Echoes are faint even if the tuning is adjusted or
the sensitivity is increased.
The magnetron in the antenna unit may have de-
teriorated. Contact a FURUNO agent or dealer
about replacement of the magnetron.
Echoes appear only in some areas and are faint. Check the sector blank settings.
Check for obstructions around the antenna.
Echoes are displayed where there is no targets. False images can occur due to various factors.
Adjust the sensitivity, sea clutter, etc. appropri-
ately.