3. MAINTENANCE, TROUBLESHOOTING
14
3.3 Replacement of Fuse
The fuse in the supplied cable assembly protects the equipment from overcurrent and
equipment fault. If the fuse blows, find the cause before replacing the fuse. Use the
correct fuse. A wrong fuse can cause fire, injury, or damage the equipment. If the fuse
blows again, contact your dealer for advice.
3.4 Replacement of Parts
Magnetron
When the life of the magnetron is reached, targets are faint and eventually no targets
appear on the display. If this occurs, contact a FURUNO agent or dealer about re-
placement of the magnetron.
Antenna motor
When the antenna motor reaches the end of its life, the antenna may stop rotating or
emit abnormal noise. If you experience any of those symptoms, contact a FURUNO
agent or dealer about replacement of the antenna motor.
Name Type Code No.
Fuse FRU-60V-FU-5A 000-194-913
Name Type Code No. Estimated life
Magnetron M1653 000-199-065 Approx. 5,000 hours
Name Type Code No. Estimated life
Motor RM-00376 000-198-794 Approx. 5,000 hours
WARNING
Use the proper fuse.
Use of a wrong fuse can cause fire,
injury, or damage the equipment.
Fuse holder
How to replace the fuse
Open the fuse holder cover and replace
the fuse. Close the cover.
Cable assembly