EasyManua.ls Logo

Furuno FAR-2018-MARK-2 - 5.8.2 How to set the plotting interval

Furuno FAR-2018-MARK-2
332 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. VIDEO PLOTTER OPERATION
5-13
5.8.2 How to set the plotting interval
1. Open the menu.
2. Select [2 MARKS].
For A/B/W-types with Radar Plotter functionality, select [2 MARKS•CHART].
3. Select [7 TRACKS].
4. Select [2 OWN TRACK] or [3 TARGET TRACK] as appropriate.
Note: For IMO/R-types, [3 TARGET TRACK] is not shown.
5. Select [3 SAVE INTERVAL].
6. Select the appropriate setting, then left-click.
The following tables show the relation between plotting interval settings and max-
imum track recording time. Note that the maximum recording time is different for
own tracks and target tracks.
Own track recording times
Target track recording times
Note: To hide own ship or target past tracks, set the interval to [OFF]. To hide both
tracks, set the interval for both own ship and targets tracks to [OFF]. Tracks plot-
ted after the setting is set to [OFF] are hidden. Previously plotted tracks remain
on-screen.
7. Close the menu.
Interval Max. Recording Time Interval Max. Recording Time
10 s 56 hours 3 min 1000 hours
30 s 167 hours 6 min 2000 hours
1 min 333 hours 15 min 5000 hours
2 min 667 hours DRAW ONLY No track data recorded.
Interval
Max. Recording Time
(One target only)
Max. Recording Time
(15 targets)
10 s 42 hours 3 hours
30 s 125 hours 8.5 hours
1 min 250 hours 16.5 hours
2 min 500 hours 33.5 hours
3 min 750 hours 50 hours
6 min 1500 hours 100 hours
15 min 3750 hours 250 hours
DRAW ONLY No track data recorded. No track data recorded.