5. MAINTENANCE, TROUBLESHOOTING
5-3
5.4 Diagnostic Test
The diagnostic test checks the equipment for proper operation.
1. Rotate the [FUNCTION] switch fully clockwise to select MENU.
2. Press the [] key to select the menu title area at the top of screen.
3. Press the [+] key to select SYSTEM.
4. Press the [] or [] key to select TEST MODE.
5. Press the [+] key to open the TEST menu.
DISP ALM TX/RX E/S SYSTEM
Menu for diagnostics.
[-/+]: Change set, [EXIT]: Exit
TEST MODE
DIAGNOSTICS : NO
TEST PATTERN : NO
HI FREQ
HI FREQ : 200 kHz : 200 kHz
LOW FREQLOW FREQ : 50 kHz : 50 kHz
Press and hold [MARKER] key more than
3 sec to exit from TEST MODE.
Test menu
6. Press the [+] key twice to select YES in the setting window.
[ ] : YES[ ] : NO
Test setting window
7. The ROM, SRAM, DRAM and NMEA check results appear. Water
temperature and speed also appear if appropriate sensor is connected.
Program No. 0252307-03.XX
ROM OK
SRAM OK
DRAM OK
NMEA OK*
Temp. SENSOR +85.5˚F
Speed SENSOR 8.0 kt
Press and hold [MARKER] key more than 3 sec to exit.
XX: Version No.
*: Requires special cable to check.
O O O 238
O 8 O 6
* O O O 255
ROM, SRAM, DRAM and NMEA test
results are shown as OK or NG (No Good).
Panel window
For testing controls.