7. NBDP SYSTEM OVERVIEW
7-2
Communication status screen
Features of the IB-583
The IB-583 has a battery (Type: CR2450-F2ST2L, Code no.: 000-144-941) on its
TERM/CPU Board (16P0209) and its life is about six years. When the voltage of the
battery gets low, the time is wrong. When this occurs, contact your dealer about re-
placement of the battery.
Russian mode
The terminal unit is fitted with both English and Russian modes. Select the desired
mode as below:
“English-mode”: Turn on the terminal unit while pressing the E key.
“Russian-mode”: Turn on the terminal unit while pressing the R key.
This mode is stored.
In “Russian-mode”, there are two input shift status; “English-shift” and “Russian-shift”.
In the “Russian-shift” status, the alphabet keys are used as Cyrillic keys.
Station Name :
Frequency (T/R) : . / . (kHz) Comm Mode : AUTO
Comm Status : Connect Send Lock Error
Sending Volume : (%) Error : 0 ARQ Time : 0(sec)
1:File 2:Edit 3:Operate 4:Window 5:Station 6:System 7:WRU 8:HR 9:Over 10:Break
10-Apr-2012 15:10:30 UTC Caps E
ng
Date and time: day-month-year, hour: min: sec (see page 7-8.)
Time system (see page 7-7)
Caps: On caps lock
No indication: Not on caps lock
Eng: English mode
Rus: Russian mode
(see page 7-2)
Ship’s name registered in the station list
(see section 8.3).
ID no. for the called party (see paragraph 8.1.2)
TX frequency (1605.0 - 27500.0 kHz)
(see section 10.1)
Communication mode
(see paragraph 10.4)
The current communication status is highlighted.
Connect: When connecting
Send: When your station is an information sending station
Lock: When synchronization is completed
Error: When required resending in ARQ mode
Percentage of message transmitted
(see page 10-4)
Number of errors in ARQ mode
Communication time
in ARQ mode
Station Name :
Frequency (T/R) : . / . (kHz) Comm Mode : AUTO
Comm Status : Connect Send Lock Error
Sending Volume : (%) Error : 0 ARQ Time : 0(sec)
10-Apr-2012 15:10:30 UTC Caps Eng
Station Name :
Frequency (T/R) : . / . (kHz) Comm Mode : AUTO
Sending Volume : (%) Error : 0 ARQ Time : 0(sec)
Station Name :
Frequency (T/R) : . / . (kHz) Comm Mode : AUTO
Comm Status : Connect Send Lock Error
Sending Volume : (%) Error : 0 ARQ Time : 0(sec)
10-Apr-2012 15:10:30 UTC Caps Eng
Sending Volume : (%) Error : 0 ARQ Time : 0(sec)
10-Apr-2012 15:10:30 UTC Caps Eng
Station Name :
Frequency (T/R) : . / . (kHz) Comm Mode : AUTO
Comm Status : Connect Send Lock Error
Sending Volume : (%) Error : 0 ARQ Time : 0(sec)
10-Apr-2012 15:10:30 UTC Caps Eng
Station Name :
Frequency (T/R) : . / . (kHz) Comm Mode : AUTO
10-Apr-2012 15:10:30 UTC Caps Eng
RX frequency (0.1 - 29999.9 kHz)
(see section 10.1)
For IB-583, year-month-day
Here is the message area.
The cursor at the left bottom of the
screen flashes during operation.
2012-04-10
for IB-583
ARQ Error
for IB-583