2
Choosing Datum
1. Press the MENU key.
2. Choose GPS SETUP and then press the
ENT key.
SYSTEM SETUP
DATUM : WGS84
UNITS : kt
TIME DIFF : +00:00
TIME DISP : 24 HOUR
TEST?
DEMO : OFF
EXCHANGE BATTERY?
3. Choose DATUM and press the [ENT]
key.
4. Choose the Datum which you are
currently using and then press the ENT
key.
5. Press the DISP key to finish.
Satellite Status
1. Press the MENU key.
2. Choose SATELLITE and then press the
ENT key.
GPS1
N
DOP
1. 5
3D
DOP
06
04
05
01
10
12
08
North
Position-
fixing
status
Antenna
element
no.
Elevation
angle 45
°
Elevation
angle 5
°
23
- -
07
02
RX signal
level
Satellite used in
fixing position
(white on black)
14
18
- -
- -
9
30
- -
- -
24
18
134
WAAS
3. Use [left] or [right] arrow to choose
antenna element for which to confirm
receiving status.
4. Press the DISP key to finish.
Resetting Distance Run
1. Press the MENU key.
2. Choose TRIP MENU and then press the
ENT key.
3. Choose RESET DISTANCE and then
press the ENT key.
RESET DISTANCE?
ARE YOU SURE?
YES NO
4. Choose YES and then press the ENT
key.
5. Press the DISP key to finish.
Automatic DGPS Position
Fixes
1. Press the MENU key.
2. Choose WAAS/DGPS and then press
the ENT key.
WAAS/DGPS
MODE : GPS
WAAS SEARCH: AUTO 134
CORRECTIONS DATA SET: 00
DPGS STATION: AUTO
RATE: 000BPS
FREQ: 310.0kHz
STATION: GOOD DATA:GOOD
SIG. S: 55.2 dB SNR: 22.0 dB
3. MODE is selected; press the ENT key.
GPS
WAAS
DPGS
AUTO
4. Choose DGPS and then press the ENT
key.
5. Choose DGPS STATION and then press
the ENT key.
AUTO
MANUAL
6. Choose AUTO and then press the ENT
key.
7. Press the DISP key to finish.