2. WIRING
2.1 Connection
Connect the equipment, referring to the interconnection diagram at the back this
manual.
GPS Antenna
GSC-001 or
GPS-017S
PC
150M-W2VN
or FAB-151D
Either one
RG-10U/Y
RG-10U/Y
Attached to Distributor
(approx. 1m)
Distributor unit
DB-1
AC
IN
DC
IN
DC
OUT
12-24 VDC
(Connect to the alternative
power source.)
100/110/115/200/
220/230 VAC
Power Supply
PR-240
DPYC-2.5
GPS/VHF Conbined
Antenna GVA-100
8D-FB-CV, 30 m/50 m: Option
RG-10U/Y: Local supply
: Standard
: Option
: Local Supply
DPYC-1.5**
0.6 m
*
*
*
0.8 m
: Ground is not required.
BREAKER
6.3A
GPS ANT
PC
VHF ANT
Other external device
(See next page.)
Ground
IV-2.0sq
Transponder unit
FA-1501
*,**: See page 14.
12-24 VDC
Monitor unit
FA-1502
IV-1.25sq
MJ-A3SPF0013
3.5m
MJ-A10SPF0012
5/10/25/50/100m
IV-1.25sq