GOVERNORTO
s4HEMAXIMUMSPEEDCANBEVERIlEDATTHE-!8
speed display, however this could show some un-
locked main rotor condition which is not accurate.
Reference
The transmitter EPA function can also be used to
change the point 1 and point 3 speed settings to a
certain extent. The amount of this change is pro-
portional to the difference between the point 1 and
point 3 set speed and the point 2 set speed. For
example, if point 1 is set to 1300rpm and point
2 is set to 1500rpm, and the transmitter EPA is
changed from 20 to 100%, the point 1 speed will
change from 1460 to 1300rpm. The transmitter
EPA function has very little effect on the point 2
speed setting.
Speed
Point 3
Point 2
Point 1
Neutral
Speed setting
channel travel
The speed changes linearly on a line connecting
points 1, 2, and 3.