This sets the delay of the revolution from high to
low. Pushing data+ or – key, the value is changed.
(9) Start delay
default:
5
range:
2
20
This sets the delay during the starting of the
governor. Pushing data+ or key, the value is
changed.
(10) Low limit at hovering
default:
25 %
range:
0
80 %
This sets the throttle low limit during hovering
revolution to avoid too lean a carburetor. Pushing
data+ or – key, the value is changed.
(11) Low limit at idle up
default:
45 %
ranges:
10
80 %
This sets the throttle low limit during idle up
revolution to avoid too lean a carburetor. Pushing
data+ or – key, the value is changed.
(12) Governor data reset