TROUBLESHOOTING
Problem Causes Solution
Energizer has started to run
slowly
The internal temperature of
the energizer is too high
Mount the energizer in a cool
area, out of direct sun and
with adequate venlaon.
Displaying Error 11 Mains voltage is too high Have your power supply
checked by a professional
electrician.
Displaying Error 12 Mains voltage is too low Have your power supply
checked by a professional
electrician.
Displaying Error 14 - 19 Internal energizer fault Turn energizer o for 30
seconds then turn back on. If
the error remains return the
energizer to your Gallagher
dealer for servicing.
Displaying Error 21 Dead zone Check that the zone device
is connected and working
correctly.
Energizer output voltage is
low
There is a fault on the fence Remove any excess grass
growth or short circuits on
the fence.
Earth voltage is too high Earth system is inadequate Check connecons to the
earth system. Add extra
earth stakes.
No output and display shows
( - - )
Energizer is in standby mode Exit standby mode by
pressing the standby buon
on the controller.
WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT
This symbol on the product indicates that this product, packaging and with special
care of the baery must not be disposed of with other waste. Instead, it is your
responsibility to dispose of your waste equipment by handing it over to a designated
collecon point for the recycling of waste electrical and electronic equipment. The
separate collecon and recycling of your waste equipment at the me of disposal
will help conserve natural resources and ensure that it is recycled in a manner that
protects human health and the environment. For more informaon about where
you can drop o your waste equipment for recycling, please contact your local city
recycling oce or the dealer from whom you purchased the product.