EasyManua.ls Logo

Gamatech PK300DC - User Manual

Default Icon
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PK300DC/PK350DC
Swing Gate Opener
User Manual

Questions and Answers

Summary

Safety Instruction

Packing List

Packing List (Optional)

List of optional accessories included with the gate opener system.

Technical Parameters

Installation

Installation Drawing

Diagram illustrating the installation layout of the gate opener components.

Main Engine and Accessory Sizes

Details on the dimensions and physical specifications of the main engine and associated parts.

Installation Steps

Detailed instructions for installing the gate opener system.

Preparation Steps

Confirms door operation, sets lock distance, and determines mounting height for the main engine.

Accessory Installation

Instructions for installing wall, connecting, and front mounting brackets for the main engine.

Manual Release and Engine Unlocking

Procedure to unlock the main engine using the manual release bar.

Main Engine Installation

Detailed steps for physically mounting and connecting the main engine to the gate.

Installation Scenarios and Angle Limits

Guidance on inward/outward opening directions and associated maximum swing angles.

Control Box Size

Dimensions of the control box unit.

Warnings

Control Board Wiring

Control Board Terminals and Functions

Detailed explanation of control board terminals, inputs, outputs, and their functions.

Inputs Status

Trimmer Settings

Board Settings

Base Menu Operations

Guide to accessing and using the base menu for operating logic, learning codes, and setting times.

Base Menu Descriptions

Detailed explanations for operating logic, transmitter learning, and working time settings.

Transmitter Code Management

Procedure for learning and removing transmitter codes from the control unit.

Working Time Learning

Steps for learning and setting automatic or manual working times for the gate.

DM Dead Man Mode

Advanced Menu

Advanced Menu Map

Visual representation of the advanced menu structure and available options.

Advanced Menu Functions

Detailed explanations of functions like working times, single wing mode, and factory defaults.

Advanced Transmitter & Radio Settings

Configuration for analogue edges, automatic learning, radio modes, and step-by-step operation.

Default Settings (Factory Presets)

Others

Maintenance

Guidance on monthly checks and regular inspection for gate opener safety and operation.

Troubleshooting

Warranty

Overview

This document is a user manual for the PK300DC/PK350DC Swing Gate Opener. It provides safety instructions, a packing list, technical specifications, installation guidelines, control board wiring, and troubleshooting information.

Function Description

The PK300DC/PK350DC Swing Gate Opener is designed for single-leaf swing gates. It utilizes a worm and worm gear combined with screw rod transmission for its drive mechanism. The gate opener is intended for installation within an enclosure or yard for protection. It can be controlled via a remote-control unit, which operates in either single-button or three-button mode depending on the specific gate opener type. The system includes safety features such as the ability to unlock the main engine and gate for manual operation using a disengagement wrench. The control unit supports various input types, including photocell, photo stop, analog opening/closing edge, start, and pedestrian start. It also features adjustable slowdown speed and obstacle detection sensitivity. The system can be configured for automatic closing, condominium function, and single-wing mode.

Important Technical Specifications

Model Comparison: PK300DC vs. PK350DC

Specification PK300DC PK350DC
Power Supply 220V/50Hz; 110V/60Hz 220V/50Hz; 110V/60Hz
Motor Power 80W 80W
Gate Moving Speed 18-22 seconds per 90° (approx) 18-22 seconds per 90° (approx)
Max. Single-Leaf Weight 300Kg 300Kg
Max. Single-Leaf Length 2.5M 3.0M
Max. Piston Stroke 34cm 54cm
Max. Force 1500N 1500N
Remote Control Distance ≥30m ≥30m
Remote Control Mode Single button mode Single button mode
Storage Battery (optional) 24V or 12 VDC 24V or 12 VDC
Noise ≤58dB ≤58dB
Working Duty S2, 30min S2, 30min
Recording of Up Remote Controls 25 25
Frequency 433.92 MHz 433.92 MHz
Working Temperature -20°C - +70°C -20°C - +70°C
Package Weight 17Kg 19Kg

Control Board Wiring Details

The control board supports various connections:

  • Power Supply: 230Vac input, with a transformer providing 240/22VAC 120VA. Battery backup options for 24V or 12V are available.
  • Inputs:
    • Antenna (1, 2)
    • Start input (NO) for full gate opening (3)
    • Pedestrian start in (NO) for motor 2 opening (4)
    • Common (5, 10, 12)
    • Photocell input (NC) (6)
    • Photo stop input (NC) (7)
    • Analog opening edge input (8K2 ohm) (8)
    • Analog closing edge input (8K2 ohm) (9)
    • Stop input (NC) (11)
  • Outputs:
    • Power supply output 12Vdc 250mA (13-14)
    • Electric lock output (15-16)
    • Flashing light output 12/24V 1A (17-18)
    • Output motor 1 (8A) (19-20)
    • Output motor 2 (8A) (21-22)
  • Trimmers:
    • TR1: Slowing down speed trimmer
    • TR2: Obstacle detection sensibility trimmer
  • Buttons: TS1-TS3 (up/down), TS2 (Enter)
  • Display: DSP
  • Fuses: F2 (Battery fuse 10A Fast), FS1-FS2 (Backup battery input 12/24Vdc)
  • Selector: J1 (Backup battery voltage selector 12/24V)

Usage Features

  • Remote Control: The gate opener is operated via a remote-control unit. The indicator light on the remote flickers when a button is pressed.
  • Manual Operation: In case of power failure or maintenance, the main engine and gate can be unlocked using a disengagement wrench for manual operation.
  • Quick Installation: The system offers a "Quick installation" feature to automatically program working times. By opening both wings and holding the "up" button until "AU" is displayed, the control unit will perform tests and learn the working times.
  • Auto Learning Transmitters: New transmitters can be learned quickly without accessing the base menu. Transmit three times with the new remote, with at least a 1-second pause between transmissions.
  • Base Menu Settings: The base menu allows configuration of:
    • Operating Logic (OL): Step-by-step logic (5T), automatic closing with stop function (At), automatic closing for condominium function (CD).
    • Learning/Removing Transmitters (LC): Learn transmitters on channel 1 (C1) or channel 2 (C2), or delete all transmitters (Rt).
    • Learn Working Times (LT): Automatic (AU) or manual (MN) learning procedures.
    • Set Pause Times (5P): Adjustable pause time between 0 and 99 seconds.
    • Dead Man Mode (DM): Allows individual control of motor 1 (01 open, C1 close) and motor 2 (02 open, C2 close).
  • Advanced Menu Settings: The advanced menu provides more detailed configuration options:
    • Working Times (TM): Modify working times for motor 1 (T1), slowdown for motor 1 (S1), motor 2 (T2), slowdown for motor 2 (S2), motors delay opening (DO), motors delay closing (DC), and electric lock activation time (TL).
    • Single Gate Mode (5G): Verify or set if the gate operates in single-wing mode (motor 2).
    • Load Factory Defaults (d2): Resets all settings to factory defaults.
    • Release End Travel Torque (RC): Enables motors to reverse direction briefly at the end of travel to release torque.
    • Opening Analog Edge (EO): Enables the analog edge input during the opening period.
    • Closing Analog Edge (EC): Enables the analog edge input during the closing period.
    • Auto Learning Transmitters (AR): Enables the quick learning feature for new transmitters.
    • Kickback Stroke (c5): Enables a stroke at the start to unlock the electric lock and a final stroke to lock it.
    • Radio Mode (rm): Modifies how transmitters work with the control unit, including step-by-step mode (5T) and different button configurations (r1, r2).
  • Safety Stopper: Essential for preventing the gate from exceeding its range. For outward-opening gates, a safety block is required at the OPEN limit position. For inward-opening gates, a safety stopper is needed at the CLOSE limit position.

Maintenance Features

  • Regular Inspection: It is recommended to check the gate's normal operation every month.
  • Infrared Protector: For enhanced safety, it is suggested to equip each gate with an infrared protector and conduct regular inspections.
  • Professional Installation and Maintenance: All installation and maintenance procedures must be carried out by professionals.
  • Cable Protection: To ensure normal operation and prevent cable damage, PVC pipes should be used for laying motor, power, and control cables, with separate pipes for (motor and power cable) and (control cable).
  • Troubleshooting Guide: The manual includes a troubleshooting section to address common issues such as the gate not opening/closing, remote control not working, gate not moving smoothly, and motor output force problems. Solutions range from checking power supply and fuses to adjusting trimmers and removing obstacles.
  • Warranty: The product comes with a 1-year warranty from the date of invoice, covering repairs or replacements for quality problems, provided there is no unauthorized dismantling or damage due to incorrect use or human error. A maintenance record section is included to log check dates, content, and the person who maintained the device.

Gamatech PK300DC Specifications

General IconGeneral
BrandGamatech
ModelPK300DC
CategoryGate Opener
LanguageEnglish