TR-HT2xx LED Controller - User Manual
Error number Reason
Err 40, 41, 45
Fatal error:
The unit is outputting more current than
was expected.
Err 42 The output current is too high.
Err 43 The requested output current requires too high a
voltage.
Err 44
Fatal error
:The TR-HTis too hot. The unit has a
thermal cut out which operates at approximately
65°C to 70°C depending on conditions.
Err 46 The maximun average power output has been
exceeded. Reduce the brightness in the
configuration.
Err 47 The controller was unable to reach a stable output
for this light. Try reducing the brightness in the
configuration.