Garden pump
Unit Value
(Art. 9050)
Value
(Art. 9054)
Value
(Art. 9056)
Mains frequency Hz 50 50 50
Max. delivery capacity l/h 4100 4200 4300
Max. pressure /
Max. delivery head
bar /
m
3.6
36
3.9
39
4.3
43
Max. self-priming suction
height
m 8 8 8
Permitted internal pressure
(delivery side)
bar 6 6 6
Power cable m
1.5
(H07RN-F)
1.5
(H07RN-F)
1.5
(H07RN-F)
Weight without cable
(approx.)
kg 5.6 5.8 6.3
Sound pressure level L
pA
Distance: 1 m
5 m
10 m
dB
64
50
44
63
49
43
65
51
45
Sound power level L
WA
1)
:
measured / guaranteed
Uncertainty k
WA
dB (A)
73 / 75
2.52
71 / 74
2.58
73 / 75
2.20
Max. media temperature °C 35 35 35
Measuring process complying with:
1)
RL 2000/14/EU
8. ACCESSORIES / SPARE PARTS
GARDENA Suction Hoses Kink-proof and vacuum-proof, optionally available by the metre
Art. 1720 / 1721 (19 mm (3/4") / 25 mm (1")) without connecting
fittings or in fixed length Art. 1411 / 1418 complete with connect-
ing fittings.
GARDENA Suction Hose
Fitting
For connection on the suction side. Art. 1723 / 1724
GARDENA Pump Connection
Set
For connection on the delivery side. Art. 1750 / 1752
GARDENA Suction Filter
with backflow preventer
To equip suction hoses with backflow
preventer sold by the meter.
Art. 1726 / 1727 /
1728
GARDENA Pump Preliminary
Filter
Recommended for pumping sandy water. Art. 1730 / 1731
GARDENA Bore Hole Suction
Hose
For vacuum-resistant connection of the pump
to boreholes or pipe networks. Length 0.5 m.
With 33.3 mm (G1) female thread at both ends.
Art. 1729
GARDENA Floating suction
system
For dirt-free suction below the water surface. Art. 1417
GARDENA Quick coupling For pressure-side connection of 1" pressure
hoses.
Art. 7109 / 7103
9. SERVICE
Please contact the address on the back page.
10. DISPOSAL
10.1 Disposal of the pump:
(according to Directive 2012/19/EU)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your local recycling collection
centre.