12
GB
Fault Possible cause Remedy
Watering is not switched on Valve has been closed manually. v Turn Run Time button to a
although soil is dry watering duration.
The control panel has not been v Insert control panel
inserted correctly. correctly.
Watering is switched on Soil Moisture Sensor not v Position Soil Moisture
although soil is damp positioned in watering area. Sensor in watering area.
Switching controller too far v Turn switching controller to
to the right on “Damp”. the left accordingly.
Defective or loose sensor cable. v Check sensor cable and
connections.
Air trapped at sensor tip. v Remove trapped air (see
4. Initial Operation
““Plant”
Soil Moisture Sensor”
).
Automatic Irrigation Set Minimum flow rate below v Connect more drip heads.
does not close below 20 l/h.
Battery display of Soil Batteries of Soil Moisture v Replace batteries ofSoil
Moisture Sensor flashing Sensor spent / inserted Moisture Sensor / insert
incorrectly / wrong batteries correctly/ use alkaline
used. batteries.
Soil Moisture Sensor defective. v Contact GARDENA Service.
Error indicator of Batteries of Soil Moisture v Replace batteries ofSoil -
Water Timer flashing Sensor spent / inserted Moisture Sensor / insert
incorrectly / wrong battery correctly/ use alkaline
used. battery.
Batteries of Soil Moisture Sensor v Replace batteries of Soil
are flat. Moisture Sensor.
Cable of Soil Moisture Sensor v Replace cable of Soil
defective. Moisture Sensor.
Defective or loose sensor cable. v Check sensor cable and
connections.
A
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
authorised by GARDENA.
9. Accessories
GARDENA Extension Cable Used to extend sensor cable to Art. 1186
(length: 10 metres) max. 105 metres.
GARDENA sensor tip For replacement of damaged Obtainable via
with felt sensor tip. GARDENA Service
1835-29.960.02_12.03.2007.qxd 15.03.2007 15:52 Seite 12