EasyManua.ls Logo

GarrettCom Magnum 3000 - Page 9

GarrettCom Magnum 3000
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Magnum 3000 Stackable Hubs Installation and User Guide (07/06)
2
www GarrettCom com
..
DC Power Supply (Options)
-48VDC Power Input Voltage : 36 to 72 VDC
24VDC Power Input Voltage : 20 to 36VDC
125VDC Power Input Voltage : 120 to 300VDC
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above
For Dual Source and Redundant DC for –48VDC, 24VDC Power &
125VDC supply options (Optional), see Appendices.
Packaging
Enclosures: High strength sheet metal, suitable for wiring closet
shelf, rack or table-top mounting.
Dimensions: Models 3024, 3012, 3000-AGT: 9.0 in x 17.0 in x 1.75 in
(22.9 cm x 43.2 cm x 4.45 cm)
Weight: Model 3024: 5.0 lbs (2.3 Kg), Model 3012 and
3000-AGT:4.0 lbs (1.8 Kg)
Cooling method: Models 3024, 3012, 3000-AGT: Convection except
3012 and 3024 w/ embedded agent: Fan cooled, internal @ 7cfm
LED Indicators on Chassis Front
PWR - Power, Green LED, steady on when AC power is applied.
LINK - (Models 3024 & 3012) Per RJ-45 port, Steady On when twisted
pair link is operational, flashing if the port is partitioned by hardware
RX - (Models 3024 and 3012) Per RJ-45 port, Receive, Green LED,
blinks to indicate activity of data being received on the port.
Agency Approvals
UL Listed (UL 1950), cUL, CE
Emissions: meets FCC Part 15 Class A
Optional: ETSI and NEBS L3 Certified
Warranty
Three years, return to factory Made in USA

Table of Contents

Related product manuals