5. Save the changes by clicking "SAVE".
Recommended values
In standard replicas, we recommend not exceeding the default motor values:
Rotation speed - 30000 RPM
Torque - moderate
Caution
Exceeding these values may result in damage to the internal parts of the gearbox. Using values higher than recommended is at your own
risk.
GATE Enterprise is not responsible for damage to other mechanical or electronic parts that result indirectly from damage to other
components of the gearbox.
Restoring the default settings of the G5 motor
Note
Restoring the default settings will set the following values:
Rotation speed - 30000 RPM
Torque - moderate
Restoring the default settings is possible after connecting the G5 brushless motor to the GCS app. Follow these steps:
1. Launch the GCS app and connect it to the selected ASTER II Bluetooth® or TITAN II Bluetooth® device that is connected to the G5
motor.
2. Go to the "General" tab.
3. Click "Smart Brushless G5 Motor Control".
4. Select "Restore Default Settings".