34 489 GENERATOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
25A9 RTD #7 Name 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #8
25E0 RTD #8 Application 0 to 4 1 F121 2
25E1 RTD #8 Alarm 0 to 2 1 F115 0
25E2 Assign Alarm Relays (2-5) 1 to 4 1 F50 16
25E3 RTD #8 Alarm Temperature 1 to 250 1 °C F1 80
25E4 RTD #8 Alarm Events 0 to 1 1 F105 0
25E5 RTD #8 Trip 0 to 2 1 F115 0
25E6 RTD #8 Trip Voting 1 to 12 1 F122 8
25E7 Assign Trip Relays (1-4) 0 to 3 1 F50 1
25E8 RTD #8 Trip Temperature 1 to 250 1 °C F1 90
25E9 RTD #8 Name 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #9
2620 RTD #9 Application 0 to 4 1 F121 2
2621 RTD #9 Alarm 0 to 2 1 F115 0
2622 Assign Alarm Relays (2-5) 1 to 4 1 F50 16
2623 RTD #9 Alarm Temperature 1 to 250 1 °C F1 80
2624 RTD #9 Alarm Events 0 to 1 1 F105 0
2625 RTD #9 Trip 0 to 2 1 F115 0
2626 RTD #9 Trip Voting 1 to 12 1 F122 9
2627 Assign Trip Relays (1-4) 0 to 3 1 F50 1
2628 RTD #9 Trip Temperature 1 to 250 1 °C F1 90
2629 RTD #9 Name 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #10
2660 RTD #10 Application 0 to 4 1 F121 2
2661 RTD #10 Alarm 0 to 2 1 F115 0
2662 Assign Alarm Relays (2-5) 1 to 4 1 F50 16
2663 RTD #10 Alarm Temperature 1 to 250 1 °C F1 80
2664 RTD #10 Alarm Events 0 to 1 1 F105 0
2665 RTD #10 Trip 0 to 2 1 F115 0
2666 RTD #10 Trip Voting 1 to 12 1 F122 10
2667 Assign Trip Relays (1-4) 0 to 3 1 F50 1
2668 RTD #10 Trip Temperature 1 to 250 1 °C F1 90
2669 RTD #10 Name 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #11
26A0 RTD #11 Application 0 to 4 1 F121 4
26A1 RTD #11 Alarm 0 to 2 1 F115 0
26A2 Assign Alarm Relays (2-5) 1 to 4 1 F50 16
26A3 RTD #11 Alarm Temperature 1 to 250 1 °C F1 80
26A4 RTD #11 Alarm Events 0 to 1 1 F105 0
26A5 RTD #11 Trip 0 to 2 1 F115 0
26A6 RTD #11 Trip Voting 1 to 12 1 F122 11
26A7 Assign Trip Relays (1-4) 0 to 3 1 F50 1
26A8 RTD #11 Trip Temperature 1 to 250 1 °C F1 90
26A9 RTD #11 Name 0 to 8 1 F22 _
RTD TEMPERATURE / RTD #12
26E0 RTD #12 Application 0 to 4 1 F121 3
26E1 RTD #12 Alarm 0 to 2 1 F115 0
26E2 Assign Alarm Relays (2-5) 1 to 4 1 F50 16
26E3 RTD #12 Alarm Temperature 1 to 250 1 °C F1 60
26E4 RTD #12 Alarm Events 0 to 1 1 F105 0
26E5 RTD #12 Trip 0 to 2 1 F115 0
26E6 RTD #12 Trip Voting 1 to 12 1 F122 12
Table CG–1: 489 Memory Map (Sheet 22 of 30)
ADDR Name RANGE STEP UNITS FORMAT DEFAULT
1, 2, 3 See Table footnotes on page page 42