Parameter Number Parameter Description Default Value 2 Setup Change During Operation Conversion Index Type
6 - 00 Live Zero Timeout Time 10 s All set-ups TRUE 0 Uint8
6 - 01 Live Zero TimeoutFunction [0] Off All set-ups TRUE - Uint8
6 - 10 Terminal 53 Low Voltage 0.07 V All set-ups TRUE -2 Uint16
6 - 11 Terminal 53 High Voltage 10 V All set-ups TRUE -2 Uint16
6 - 12 Terminal 53 Low Current 0.14 mA All set-ups TRUE -2 Uint16
6 - 13 Terminal 53 High Current 20 mA All set-ups TRUE -2 Uint16
6 - 14 Terminal 53 Low Ref./Feedb. Value 0 All set-ups TRUE -3 Int32
6 - 15 Terminal 53 High Ref./Feedb. Value 50 All set-ups TRUE -3 Int32
6 - 16 Terminal 53 Filter Time Constant 0.01 s All set-ups TRUE -2 Uint16
6 - 19 Terminal 53 mode [0] Voltage mode 1 set-up TRUE - Uint8
6 - 22 Terminal 60 Low Current 0.14 mA All set-ups TRUE -2 Uint16
6 - 23 Terminal 60 High Current 20 mA All set-ups TRUE -2 Uint16
6 - 24 Terminal 60 Low Ref./Feedb. Value 0 All set-ups TRUE -3 Int32
6 - 25 Terminal 60 High Ref./Feedb. Value 50 All set-ups TRUE -3 Int32
6 - 26 Terminal 60 Filter Time Constant 0.01 s All set-ups TRUE -2 Uint16
6 - 81 Keypad potentiometer Low Ref. 0 All set-ups TRUE -3 Int32
6 - 82 Keypad potentiometer High Ref. 50 All set-ups TRUE -3 Int32
6 - 90 Terminal 42 Mode [0] 0-20 mA All set-ups TRUE - Uint8
6 - 91 Terminal 42 Analog Output [0] No operation All set-ups TRUE - Uint8
6 - 92 Terminal 42 Digital Output [0] No operation All set-ups TRUE - Uint8
6 - 93 Terminal 42 Output Min Scale 0% All set-ups TRUE -2 Uint16
6 - 94 Terminal 42 Output Max Scale 100% All set-ups TRUE -2 Uint16
5.2.11. 6-** Analog In/Out
AF-60 LP™ Micro Drive Programming Guide
74