Installation Instructions
INSTALLING THROUGH THE WALL
Read these instructions completely and carefully.
[i] PREPARE OPENING IN WALL
Make certain a wall receptacle is available close
to the hole location or make arrangements to install
a receptacle,
The cord length for the 115-volt models is 72"
to the right and 47" to the left.
For the 230/208-volt models the cord length is 65"
to the right and 39" to the left.
MINIMUM
FINISHED
OPENING
DIMENSIONS* CASE DIMENSIONS
Height Width Height Width Depth
15¾" 26½" 15%" 26¼d' 16"
'Dimensions may need
to be increased to fit
unique situations in the
field if using case angles.
171SUPPORT REQUIREMENTS FOR AIR
CONDITIONER
The air conditioner wall case may be installed
with 1/4" rain. extension out from the inside wall
or with 1/4" rain. extension out from the outside wall.
The finished sides of the opening should be structural
wall members.
Lintel - Use a lintel in brick veneer and brick
and block types of wall to support the bricks
or blocks above the opening, Do not allow the wall
case to be used in lieu of a lintel.
Flashing -Install flashing (drip rail) as shown
to prevent water from dripping inside the wall
and down the outside of the building,
Brick veneer _....
Lintel angle _.. "-...... g
I,ii, i!l
(,f requ,red) .... _" (' , ' it_[_ Plaster line
Caulking _=--I] ),
,ona,4sides ' lit
on the outside "d-_ I'_!l:t___- Trim
and inside -,_,_
I I IUlUll I_
of the case) Caulking i (if desired)
|
(above [ Room side
below the
flashing)
Flashing
(driprail)
I
m
m
m
#
1/4" min, extension T
inside the wall from --
the trim molding
r@]SUPPORT REQUIREMENTS FOR AIR
CONDITIONER
Mortar between the case and the brick wall around
the case may be undercut at about 45° for
improved caulking,
Inside
Top ofcase ___-'-I
Caulking / Outside L Undercut
mortar