Home
GE
Circuit breakers
AKR
GE AKR User Manual
5
of 1
of 1 rating
63 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
Draw
Out
General
Purpose
Enclosure
—
NEMA
1
For
indoor
use
,
the
one
-
high
The
draw
out
mechanism
closed
door
draw
out
steel
housing
is
complete
with
a
draw
out
breaker
(
draw
out
mounting
type
letter
“
A
”
)
.
The
unit
is
wall
-
mounted
in
the
AKR
-
30
and
-
50
sizes
,
floor
-
mounted
in
the
AKR
-
75
and
-
100
sizes
.
The
draw
out
operation
features
the
same
four
posi
-
tions
and
functions
in
the
same
manner
as
described
earlier
for
draw
out
AKR
sub
-
structures
.
Breaker
position
,
though
,
is
clearly
identified
by
a
rotary
indicator
visible
through
a
door
opening
.
With
the
door
open
,
the
breaker
can
be
pulled
out
manually
from
the
DISCON
-
NECT
to
the
WITHDRAWN
position
so
that
the
breaker
is
completely
out
of
its
com
-
partment
and
ready
for
removal
.
is
externally
operated
by
a
removable
racking
handle
.
Two
mechanism
types
are
employed
.
A
breaker
-
mounted
,
screw
/
traveling
nut
type
services
the
AKR
-
30
and
-
50
frames
,
and
the
racking
handle
is
inserted
through
an
opening
in
the
breaker
escutcheon
.
The
equipment
mounted
type
mechanism
is
employed
on
the
AKR
-
75
and
-
100
models
(
mounting
type
“
A
”
break
-
ers
)
,
and
the
racking
handle
is
inserted
through
an
open
-
ing
in
the
leftside
of
the
door
.
In
both
mechanism
types
the
breaker
is
sup
-
ported
by
two
pins
protrud
-
ing
from
each
side
of
its
frame
,
these
engaging
slots
in
the
telescoping
rails
fas
-
tened
to
the
enclosure
walls
.
11
Courtesy of store.ips.us
11
13
Table of Contents
Table of Contents
2
Quick Selector Breaker / Trip Combinations
4
Breaker / Trip Combinations
4
Breaker Designations Legend
6
Enclosures and Mountings
10
Rms
16
Ratings
16
Akr - 30 S
26
Akr - 30 / 50 / T
26
Akr
26
Time Current Tripping Characteristics
40
Time Current Curves
40
Outline Dimension Drawing Numbers
54
Standards and References
60
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the GE AKR and is the answer not in the manual?
Ask a question
GE AKR Specifications
General
Standards
UL489, IEC 60947-2
Voltage Rating
600V
Mounting
Fixed, Drawout
Poles
3
Trip Unit
Electronic
Operating Temperature
+70°C
Related product manuals
GE AK-15
28 pages
GE AK-50
32 pages
GE AKF-1C
7 pages
GE AK-2-15
10 pages
GE AK-2-50
10 pages
GE AK-1-15
10 pages
GE AK-2A-15
40 pages
GE AKR Series
32 pages
GE AK-50 Series
48 pages
GE AKR-75 Series
24 pages
GE AK-1-15 Series
31 pages
GE AKR D 50H Series
260 pages