Home
GE
Circuit breakers
AKR
GE AKR User Manual
5
of 1
of 1 rating
63 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
Time
Current
Tripping
Characteristics
AKR
low
voltage
power
cir
-
cuit
breaker
time
current
curves
are
the
engineering
documents
which
define
technical
performance
char
-
acteristics
of
the
devices
.
Information
provided
on
the
time
current
curve
includes
the
following
:
•
Product
family
type
(
s
)
.
•
Specific
device
type
(
s
)
.
•
Ampere
ratings
covered
on
curve
.
•
Overcurrent
characteris
-
tics
—
long
time
,
short
-
time
,
instantaneous
,
etc
.
•
Maximum
total
clearing
time
.
•
Maximum
and
minimum
temperature
limits
.
•
Frequency
ratings
.
•
Voltage
ratings
.
•
Specific
trip
unit
ratings
.
•
Trip
unit
adjustment
ranges
.
•
Tolerances
.
Multiples
of
circuit
breaker
trip
rating
are
shown
on
the
top
and
bottom
horizontal
axis
,
with
time
in
seconds
on
the
vertical
axis
.
Approx
-
imate
minimum
and
maxi
-
mum
clearing
time
is
readily
determined
from
the
charac
-
teristics
curves
.
Tripping
characteristics
meet
ANSI
,
NEMA
and
UL
standards
for
rating
and
calibration
.
Table
39.1
AKR
Low
Voltage
Power
Circuit
Breakers
Time
Current
Curves
Trip
Device
Trip
Elements
Curve
LSI
GES
-
6227
MicroVersaTrip
®
RMS
-
9
G
GES
-
6228
LSI
GES
-
6199
MicroVersaTrip
®
G
GES
-
6195
EC
-
1
LSI
GES
-
6000
A
LI
-
1
BB
-
3
GES
-
6003
EC
-
1
B
LI
-
1
CC
-
3
GES
-
6004
LSI
GES
-
6005
LI
-
1
A
-
3
GES
-
6010
EC
-
2
/
2
A
LI
-
1
B
-
3
GES
-
6011
LI
-
1
C
-
3
GES
-
6012
39
Courtesy of store.ips.us
39
41
Table of Contents
Table of Contents
2
Quick Selector Breaker / Trip Combinations
4
Breaker / Trip Combinations
4
Breaker Designations Legend
6
Enclosures and Mountings
10
Rms
16
Ratings
16
Akr - 30 S
26
Akr - 30 / 50 / T
26
Akr
26
Time Current Tripping Characteristics
40
Time Current Curves
40
Outline Dimension Drawing Numbers
54
Standards and References
60
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the GE AKR and is the answer not in the manual?
Ask a question
GE AKR Specifications
General
Standards
UL489, IEC 60947-2
Voltage Rating
600V
Mounting
Fixed, Drawout
Poles
3
Trip Unit
Electronic
Operating Temperature
+70°C
Related product manuals
GE AK-15
28 pages
GE AK-50
32 pages
GE AKF-1C
7 pages
GE AK-2-15
10 pages
GE AK-2-50
10 pages
GE AK-1-15
10 pages
GE AK-2A-15
40 pages
GE AKR Series
32 pages
GE AK-50 Series
48 pages
GE AKR-75 Series
24 pages
GE AK-1-15 Series
31 pages
GE AKR D 50H Series
260 pages