AKRU
Fuses
Table
31.1
Gould
-
Shawmut
—
GE
AKRU
Fused
Breaker
Fuse
Cross
Reference
General
Electric
Type
J
and
L
fuses
are
now
obsolete
,
and
no
longer
used
in
type
AKRU
low
-
voltage
power
circuit
breakers
.
Gould
-
Shawmut
fuses
are
now
used
.
The
chart
cross
-
references
the
obsolete
GE
catalog
number
and
the
replacement
Gould
-
Shawmut
catalog
numbers
.
Obsolete
General
Electric
Cat
.
No
.
Gould
,
Inc
.
Equiv
.
Cat
.
No
.
Fuse
Ampere
Rating
Class
A
4
J
150
GF
8
B
150
150
200
200
200
225
225
225
250
250
250
300
300
300
J
350
350
350
400
400
400
450
450
450
500
500
500
GF
8
B
600
A
4
J
600
600
Table
31.2
Gould
-
Shawmut
—
GE
Special
“
Welder
”
Limiters
®
for
AKRU
-
30
,
-
50
Circuit
Breakers
A
4
BY
601
GF
8
B
601
601
650
650
650
700
700
700
800
800
800
1000
BG
®
1200
BG
®
1000
1000
Obsolete
Gould
,
Inc
.
Equiv
.
Cat
.
No
.
1200
1200
L
Ampere
Rating
GE
1400
1400
Cat
.
No
.
1600
1600
BG
1600
2000
2000
A
4
BX
800
A
4
BX
1000
BG
®
A
4
BX
1200
BG
®
A
4
BX
1600
BG
®
A
4
BX
2000
2000
800
GF
30
W
8
GF
30
W
10
GF
30
W
12
GF
30
W
16
GF
30
W
20
A
4
BY
2500
A
4
BX
2500
GE
®
A
4
BY
3000
"
A
4
BY
4000
®
2500
STD
2500
SPEC
GF
8
B
2500
GF
9
F
2500
AK
®
GF
8
F
3000
GF
8
F
4000
1000
1200
1600
3000
4000
2000
®
Used
on
TAK
8
SS
02
fuse
carriage
.
®
Not
class
L
fuse
—
this
is
a
special
“
limiter
”
in
size
®
Used
on
TAK
9
SS
02
fuse
carriage
,
and
electrical
properties
(
has
only
short
circuit
protection
)
.
®
The
“
limiters
”
are
identical
in
size
to
the
standard
class
L
fuses
;
however
they
provide
only
short
circuit
protection
.
No
overcurrent
protection
is
provided
.
®
Suffix
or
type
BG
denotes
cut
-
out
on
fuse
tang
.
®
Suffix
or
type
BG
denotes
cut
-
out
on
tang
.
Table
31.3
Allowable
Fuse
Sizes
Maximum
Gould
-
Shawmut
Class
“
L
”
Fuse
Minimum
Gould
-
Shawmut
Class
“
L
”
Fuse
Minimum
Gould
-
Shawmut
Class
“
J
”
Fuse
Rating
Plug
Rating
Breaker
Type
Frame
Size
Size
1200
A
800
A
300
A
600
A
and
Below
600
A
AKU
-
25
1600
A
1000
A
800
A
1600
A
800
A
700
A
1600
A
800
A
600
A
600
A
AKRU
-
30
,
30
S
800
A
1600
A
400
A
400
A
1600
A
300
A
300
A
1600
A
300
A
225
A
and
Below
2500
A
1600
A
2500
A
1200
A
2500
A
1600
A
2500
A
1000
A
1000
A
800
A
2500
A
800
A
1600
A
AKRU
-
50
700
A
2500
A
700
A
600
A
2500
A
600
A
500
A
2500
A
500
A
400
A
and
Below
2500
A
450
A
3200
A
and
Below
3000
A
3200
A
2000
A
AKRU
-
75
4000
A
and
Below
4000
A
AKRU
-
100
4000
A
2000
A
31
Courtesy of store.ips.us
31
33
Table of Contents
Table of Contents
2
Quick Selector Breaker / Trip Combinations
4
Breaker / Trip Combinations
4
Breaker Designations Legend
6
Enclosures and Mountings
10
Rms
16
Ratings
16
Akr - 30 S
26
Akr - 30 / 50 / T
26
Akr
26
Time Current Tripping Characteristics
40
Time Current Curves
40
Outline Dimension Drawing Numbers
54
Standards and References
60
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the GE AKR and is the answer not in the manual?
Ask a question
GE AKR Specifications
General
Standards
UL489, IEC 60947-2
Voltage Rating
600V
Mounting
Fixed, Drawout
Poles
3
Trip Unit
Electronic
Operating Temperature
+70°C
Related product manuals
GE AK-15
28 pages
GE AK-50
32 pages
GE AKF-1C
7 pages
GE AK-2-15
10 pages
GE AK-2-50
10 pages
GE AK-1-15
10 pages
GE AK-2A-15
40 pages
GE AKR Series
32 pages
GE AK-50 Series
48 pages
GE AKR-75 Series
24 pages
GE AK-1-15 Series
31 pages
GE AKR D 50H Series
260 pages