Electrical
Characteristics
AKR
-
75
/
100
Table
36.1
Charging
and
Closing
Operating
Currents
Control
Relay
“
X
”
Closing
Solenoid
Anti
-
Pump
Relay
“
W
”
Motor
Current
(
Amps
)
Charg
-
Fuse
Nominal
Control
Voltage
Freq
.
Voltage
Range
Rated
Amps
Min
.
Rated
Amps
Min
.
Rated
Amps
ing
Min
.
Selec
-
Sus
-
Hz
Inrush
Sealed
(
Volts
)
Pick
-
up
Inrush
Sealed
(
Volts
)
Pick
-
up
Inrush
Sealed
Time
(
Sec
.
)
(
Volts
)
Inrush
tion
tained
Open
Closed
Open
Closed
Pick
-
up
Open
Closed
30
38
2.7
20
A
2.0
16.5
38
.
063
.
063
4.1
4.1
2.7
22
DC
38
-
56
48
V
1.05
100
1.3
20
A
1.7
.
024
.
024
90
1.05
1.3
7
85
DC
100
-
140
25
125
V
.
68
20
A
.
015
.
015
180
.
53
.
53
200
.
68
1.7
3.2
170
DC
200
-
280
13
250
V
1.0
2.6
.
35
20
A
1.5
.
090
.
052
1.4
120
V
60
1.0
98
2.2
.
29
20
A
1.5
.
090
.
052
95
.
15
25
8.1
95
120
V
50
104
-
127
.
032
6.85
1.27
.
17
20
A
1.5
.
047
1.1
120
V
25
.
063
1.5
.
19
20
A
1.7
.
050
.
029
.
45
208
V
60
.
16
20
A
1.7
.
050
.
029
175
.
55
.
083
177
1.2
10.3
3.5
175
50
180
-
220
208
V
.
60
.
032
.
018
3.86
.
76
.
08
20
A
1.7
208
V
25
.
036
.
50
.
07
1.3
.
17
20
A
1.3
.
064
250
V
60
20
A
1.3
.
064
.
036
190
.
50
.
08
196
1.1
.
15
3.5
190
50
208
-
254
11.7
250
V
.
035
.
023
3.42
.
64
.
54
.
08
20
A
1.3
250
V
25
Table
36.2
Shunt
Trip
and
Undervoltage
Device
Operating
Currents
Undervoltage
Shunt
Trip
Nominal
Control
Voltage
Current
(
Amps
)
Current
(
Amps
)
Frequency
Operating
Voltage
Range
Operating
Voltage
Range
Hz
Inrush
Open
Sealed
Closed
Inrush
Open
Sealed
Closed
30
8.3
8.3
.
38
.
38
DC
14
24
.
19
28
60
4.5
4.5
.
19
DC
48
2.0
2.0
.
08
.
08
70
140
DC
125
280
1.0
1.0
.
04
.
04
DC
140
250
N
/
A
N
/
A
60
59
132
70
12.3
10.8
Pickup
at
80
%
of
Nominal
Control
Voltage
Drop
out
at
30
-
60
%
of
Nominal
Control
Voltage
.
66
95
127
.
24
120
60
7.6
95
127
6.7
.
75
.
25
120
50
.
10
95
127
4.7
4.1
.
31
120
25
220
3.2
2.6
.
51
.
17
60
175
208
175
220
3.8
3.1
.
30
.
10
50
208
1.9
.
05
175
220
2.1
.
14
208
25
3.9
3.4
60
190
254
.
37
.
12
240
4.7
.
34
50
190
254
4.1
.
11
240
190
254
5.8
5.1
N
/
A
N
/
A
40
240
2.1
1.9
.
16
25
190
254
.
06
240
50
315
410
2.9
2.6
.
22
.
08
380
508
3.4
3.1
60
380
.
23
.
08
480
50
380
508
7.5
7.3
.
17
.
06
480
3.5
380
508
3.3
.
05
480
25
.
11
625
2.8
2.5
.
16
.
06
575
60
475
625
5.1
4.7
.
06
50
475
.
14
575
625
3.1
3.0
.
05
25
475
.
10
575
Courtesy of store.ips.us
36
38
Table of Contents
Table of Contents
2
Quick Selector Breaker / Trip Combinations
4
Breaker / Trip Combinations
4
Breaker Designations Legend
6
Enclosures and Mountings
10
Rms
16
Ratings
16
Akr - 30 S
26
Akr - 30 / 50 / T
26
Akr
26
Time Current Tripping Characteristics
40
Time Current Curves
40
Outline Dimension Drawing Numbers
54
Standards and References
60
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the GE AKR and is the answer not in the manual?
Ask a question
GE AKR Specifications
General
Standards
UL489, IEC 60947-2
Voltage Rating
600V
Mounting
Fixed, Drawout
Poles
3
Trip Unit
Electronic
Operating Temperature
+70°C
Related product manuals
GE AK-15
28 pages
GE AK-50
32 pages
GE AKF-1C
7 pages
GE AK-2-15
10 pages
GE AK-2-50
10 pages
GE AK-1-15
10 pages
GE AK-2A-15
40 pages
GE AKR Series
32 pages
GE AK-50 Series
48 pages
GE AKR-75 Series
24 pages
GE AK-1-15 Series
31 pages
GE AKR D 50H Series
260 pages