11
Arize Element
®
L1000 Gen2 Installation Guide
3 Electrical Connections
3.1 Connect the Driver Output to Light Module
NOTE 2: To disassemble connectors, turn locking ring 1/8 of a turn counter-clockwise and separate connectors.
NOTE 1: Use 914 mm or 1828 mm extension cables if driver and light module are more than 0.6 m apart.
Align keying features of
larger output connector on
driver with connector on light
module cable.
Push connectors together until
the lock ring has snapped into
place and a click is heard.
Recommended: secure light
module cable.
1 2 3
CLICK!
Driver connections
DC Output
Dimming
AC Input
WARNING
RISK OF ELECTRIC SHOCK
Turn power OFF before inspection, installation or removal.