EasyManua.ls Logo

GE Arize Element L1000 Gen2 - Connect the Driver Input; Using Custom AC Inputs; Connecting Driver to AC Line

GE Arize Element L1000 Gen2
27 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Arize Element
®
L1000 Gen2 Installation Guide
3.2.2 Using Custom
AC Inputs
3.2.1 Connect the Driver Input
CLICK!
AC line
To driver input
Connect the yellow/green wire to
the incoming ground conductor.
Connect the brown wire to Line 1
and blue wires to Neutral or Line 2
of the incoming AC line.
>PA<
Pin
Line-to-Line
Voltage
Line-to-Neutral
Voltage
1 L2 L1 L1 L1 L2 L3
2 L3 L2 L3 N N N
PE PE PE PE PE PE PE
L=Line / N=Neutral / PE=Protective Earth
3.2.3 Connect Bead to
AC Input Leader Cable
Connect 2 beads provided, the
rst bead should be no more than
20 mm from input connector.
20mm
If you choose to use your own
custom AC input connection, use a
Wieland RST20i3 green connector
(96.031.4055.7 OR 96.031.4155.7 OR
96.031.0055.7 OR 96.031.1055.7)
and plug into the male AC connector
of the driver.
3.2.4 Connecting Driver
to AC Line
NOTE: To disassemble connectors,
insert and twist a small blade
screwdriver and then separate
connectors.
Align keying features on driver
with connector on the selected
leader cable.
Push connectors together until
a click is heard.
Secure AC input leader cable,
away from driver and light
module.
1 2 3
Connector pin-out
1
2
PE