Auxi/iaq controlsonyourZoneline.
Remote Thermostat--Class 2
_._q_en this switch is enabled (UP}, it allows the
unit to operate with a Class 2 Remote Control
Wall Them_ostat. The trait controls are disabled.
°_'%BBBI_BBBBBBBBBBBB°_'%
L CLASS2 (Remote Thermostat)
LoadShedding(CentralDesk Control)
This featm'e is active only if the trait is in
CDC mode. When this switch is enabled (UP),
the indoor tim can be tin'ned ON or OFF with
the trait controls.
°_:"BBBB_BBB BBBBBBBB°_:"
L_ LOADSHEDDING(CDC)
Freeze Sentinel
_._l_en this switch is enabled (UP), it turns OFF
the fl'eeze sentinel protection ieatm'e. With the
switch disabled (DOWN),the fl'eeze sentinel is
acti\_ted, which automatically provides heat
without user inte_ti_ce. This helps to prevent
plumbing damage by turning the heater and
indoor tim ON at 41°F and OFF at 46°E
°_"[BBBBB@BBJBBBBBBBB °'%"
t FREEZESen (FreezeSentinel)
Constant ON Fan
"_._q_enthis switch is enabled (UP),it allows the
indoor tim to run continuously at high speed,
exen if the trait is in the STOP position.
°_"BBBBBB@B BBBBBBBB °"%°
t DONST FAN(Constant
ON Fan)