CHAPTER 2: MODBUS COMMUNICATION MEMORY MAP
UR FAMILY – COMMUNICATIONS GUIDE 2-61
2
" 411C Port 1 Function 0 to 1 --- 1 F102 1 (Enabled)
" 411D Port 2 Function 0 to 1 --- 1 F102 1 (Enabled)
" 411E Port 3 Function 0 to 1 --- 1 F102 1 (Enabled)
" 411F IEC Communications Reserved (33 items) 0 to 1 --- 1 F001 0
" 4140 DNP Object 1 Default Variation 1 to 2 --- 1 F001 2
" 4141 DNP Object 2 Default Variation 1 to 3 --- 1 F001 2
" 4142 DNP Object 20 Default Variation 0 to 3 --- 1 F523 0 (1)
" 4143 DNP Object 21 Default Variation 0 to 3 --- 1 F524 0 (1)
" 4144 DNP Object 22 Default Variation 0 to 3 --- 1 F523 0 (1)
" 4145 DNP Object 23 Default Variation 0 to 3 --- 1 F523 0 (1)
" 4146 DNP Object 30 Default Variation 1 to 5 --- 1 F001 1
" 4147 DNP Object 32 Default Variation 0 to 5 --- 1 F525 0 (1)
" 4148 SCADA Protocol 0 to 2 --- 1 F629 0 (DNP 3.0)
" 4149 RS232 Baud Rate 0 to 1 --- 1 F635 1 (115200)
" 414A DNP Event Time Base 0 to 1 --- 1 F639 1 (LOCAL)
" 414B IEC 104 Event Time Base 0 to 1 --- 1 F639 1 (LOCAL)
" 414C IEC 103 Event Time Base 0 to 1 --- 1 F639 1 (LOCAL)
Communications Actual Values (Read Only)
All 4160 Modbus Available TCP/IP Connections 0 to 4 --- 1 F001 4
" 4161 DNP Available TCP/IP Connections 0 to 2 --- 1 F001 2
" 4162 IEC Available TCP/IP Connections 0 to 2 --- 1 F001 2
" 4163 MMS Available TCP/IP Connections 0 to 5 --- 1 F001 5
" 4164 PMU Available TCP/IP Connections 0 to 4 --- 1 F001 4
" 4165 SFTP Available Connections 0 to 4 --- 1 F001 4
Simple Network Time Protocol (Read/Write Setting)
All 4168 Simple Network Time Protocol (SNTP)
Function
0 to 1 --- 1 F102 0 (Disabled)
" 4169 Simple Network Time Protocol (SNTP)
Server IP Address
0 to 4294967295 --- 1 F003 0
" 416B Simple Network Time Protocol (SNTP) UDP
Port Number
1 to 65535 --- 1 F001 123
Data Logger Commands (Read/Write Command)
All except B90 4170 Data Logger Clear 0 to 1 --- 1 F126 0 (No)
Data Logger (Read/Write Setting)
All except B90 4181 Data Logger Channel Settings (16 items) --- --- --- F600 0
" 4191 Data Logger Mode 0 to 1 --- 1 F260 0
(Continuous)
" 4192 Data Logger Trigger 0 to 4294967295 --- 1 F300 0
" 4194 Data Logger Rate 15 to 3600000 ms 1 F003 60000
Clock (Read/Write Setting)
All 419F Synchronizing Source 0 to 3 --- 1 F623 0 (None)
Clock (Read/Write Command)
All 41A0 Real Time Clock Set Time 0 to 235959 --- 1 F050 0
Clock (Read/Write Setting)
All 41A2 SR Date Format 0 to 4294967295 --- 1 F051 0
" 41A4 SR Time Format 0 to 4294967295 --- 1 F052 0
" 41A6 IRIG-B Signal Type 0 to 2 --- 1 F114 0 (None)
" 41A7 Clock Events Enable / Disable 0 to 1 --- 1 F102 0 (Disabled)
Products Address Register name Range Units Step Format Default