Section 2 - Installation
19
2.8 Power Connections
The power supply options are 110/220 AC and HVDC, or +24 Vdc. All monitors,
regardless of the type of power supply that is chosen, are protected by an internal
fuse.
2.8.1 Types of Power Connections
Connect power to the monitor as shown in Table 2.10.
TABLE 2.10: Monitor Power Connections
INPUT VOLTAGE CONNECTIONS
85 Vac to 264 Vac
1
2
3
Line
Line 2/Neutral
Ground
110 Vdc to 370 Vdc
1
2
3
Line 1
Common
Ground
24 Vdc
1
2
3
+24 Vdc
Common
Ground
2.8.2 Power Electrical Connections
Use these tools and supplies to connect cable to the power terminal strip:
Wire stripper
Crimp tool
A phillips or straight screwdriver
Crimp type ring or spade lugs
3 conductor cable (maximum conductor size: 16 AWG)