330400 and 330425 Accelerometer Operation Manual
5.2.2 Environmental for the 330400 and the 330425 Accelerometer
Operating
Temperature Range
-55° to 121°C (-67° to 250°F)
Shock Limit
49030 m/s2 pk (5000 g pk) maximum
Humidity Limit
100% condensing, non-submerged. Case is
hermetically-sealed
5.2.3 Mechanical for the 330400 and 330425 Accelerometer
Dimensions
See Figure 5-1
Mounting Surface
28.6 mm (1.125 in) diameter
Mounting Torque of
Accelerometer
Case Material
Connector
Polarity
Weight
Mounting angles
3.3 ± 0.6 N-m (30 ± 5 in-lb)
304L stainless steel
3 pin, MIL-C-5015, hermetically-sealed
Pin A goes positive with respect to pin C when
acceleration is from base to connector of the transducer.
3.5 oz. typical
Any Orientation
5.2.4 Interconnect Cable for the 330400 and 330425 Accelerometer
Standard Interconnect Cable:
Size
Materials
Conductor
Insulation
Shield
Jacket
Voltage Rating
0.5 mm2 (22 AWG)
Silver Tinned Copper
Teflon Jacket
Braided Silver Tinned Copper
Tef lon
600 V
18