Group Value Displayed Failure Code Definition Setting Criteria
Sealed System / Miscellaneous
300 thru 399
F300 0 3 0 0
Excessive Compressor Run Time.
Compressor ran for 5 hours
Note: The initial cycle at
power-up is
ignored.
F301 0 3 0 1
Compressor off for 3 hours with Cooling System turned
on. (This is going to be hard to see because on some
models, this will trigger a reset)
Cooling System was on and the
compressor remained off for 3 hours.
F302 0 3 0 2
FF No Freeze Limit Tripped.
FF crossed the No Freeze Limit. Only call
once it crosses. It needs to return to
normal and then cross again to call the
FCode
handler again.
F303 0 3 0 3
FF Temp Exceeded.
F304 0 3 0 4
FZ Temp Exceeded.
F305 0 3 0 5
Dampers Stuck Closed.
F306 0 3 0 6
Damper Stuck
Open.
Sealed System Failure Codes