79
Group Value Displayed Failure Code Definition Setting Criteria
Ice Maker
600 thru 699
F600 0 6 0 0
FF Icemaker Multi
-fill 3 times the last 10
fills?
If the multi
-fill algo is active 3 times in the last 5 fills
F601 0 6 0 1
FF Icemaker Stuck in Harvest Fix Mode.
After 10 minutes, if the software is
stuck in Harvest
Fix Mode.
F602 0 6 0 2
FF Icemaker enters harvest fix mode 3
out of 10 harvests.
Icemaker logic went into Harvest fix 3 out of 10
harvests
F603 0 6 0 3
FF Icemaker enters Fault Mode
After enter into Harvest Fault
F650 0 6 5 0
FZ Icemaker Multi
-fill 3 times the last 10
fills?
If the multi-fill algo is active 3 times in the last 5 fills
F651 0 6 5 1
FZ Icemaker Stuck in Harvest Fix Mode.
After 10 minutes, if the software is stuff in Harvest Fix
Mode.
F652 0 6 5 2
FZ Icemaker enters harvest fix mode 3
out of 10 harvests.
Icemaker logic went into Harvest fix 3 out of 10
harvests
F653 0 6 5 3
FZ Icemaker enters Fault Mode
After enter into Harvest Fault
Icemaker Failure Codes