80
Group
Value Displayed Failure Code Definition Setting Criteria
External Interaction (700 thru 799)
F700 0 7 0 0
Stuck keys On ICID/ACM/ (Dispenser Boards)
Stuck Key is present on ICID/ACM. Only send
once per each stuck key.
F701 0 7 0 1
Stuck Keys on Internal Temp Board
Stuck Key is present on Internal Temp. Only
send once per each stuck key.
F702 0 7 0 2
Stuck Keys on Deli Pan
Stuck Key is present on Deli Pan. Only send
once per each stuck key
F703 0 7 0 3
Key inputs on
Deli Pan Temp Board and Door Closed
FF Door is closed and a Key Input is detected
F704 0 7 0 4
Key Inputs on Deli Pan/FP Board and Door Closed
FF Door is closed and a key input is detected
F705 0 7 0 5
Auto fill Communication Error
AutoFill Module not communicating properly
F706 0 7 0 6
Auto fill wrong version
The Version of the Auto fill module is not
compatible with the ACM Version
F707 0 7 0 7
ACM/
Comm Communication Error
COM Module not communicating properly
F708 0 7 0 8
COM Wrong
Version
COM Version is not compatible with the ACM
F709 0 7 0 9
Cold Water Cup Switch Input missing and 0x70 message
is received from COM (ACM Only)
Dispense message is received and 30
seconds later
the Cup Switch input is still not
present
F710 0 7 1 0
Cold Water Cup Switch Input present and no
dispense
message
is received from COM (ACM Only)
Cup Switch input is present for 30 seconds
and no
dispense message has been received
F711 0 7 1 1
Hot Water Cup Switch Input missing and
dispense
message
is received that requires the cup switch (ACM
Only)
Dispense message is received and 30
seconds later the Cup Switch input is still not
present
F712 0 7 1 2
Hot Water Cup Switch Input present and no
dispense
message
is received (ACM Only)
Cup Switch input is present for 30 seconds
and no
dispense message has been received
F713 0 7 1 3
FF Door open for 15 minutes without closing
Usage or door switch
F714 0 7 1 4
FF Door open for 60 min. in the last 24 hours
Usage or door switch
F715 0 7 1 5
50 FF Door Openings in the last 24 hours.
Usage or door switch
F716 0 7 1 6
FZ Door open for 15 minutes without closing
Usage or door switch
F717 0 7 1 7
FZ Door open for 60 min. in the last 24 hrs.
Usage or door switch
F718 0 7 1 8
50 FZ Door Openings in the last 24 hours.
Usage or door switch
ACM (Appliance Communication Module) Energy Management Accessory
Interaction Fault Codes