Installingthe dryer.
Locationof YourDryer
Do Not Install the Dryer:
_] Do not install the dryerin an area exposed u)
&ipping water or outside weather conditions.
]Do not install the dryerin an area where it _dll
coiile in con[act %_itll(tn[ains, (hapes, or
anything that will obsu_uct tile flow of
combustion and ventilation air.
[] Do not instafl the dryer on carpet.
Floor MUSTbe solid xdth a maximum sh)pe of 1"
(2.54 (rn).
Installation in Recess or Closet
[]This dryer MUST be exhausted outdoors.
]No other/uel burning applian(e shall be
installed in tile same (It)set as tile GAS DRYER.
[]Your (hyer needs the space around it for proper
ventilation, DONOTINSTALLYOURDRYERIN A
CLOSETWITHA SOLIDDOOR.
[]
A minimum of 120 square inches (774.2 square
(m) of opening, equally dMded at tile top and
bottom of tile (loot, is required. Air openings are
required to be unobstructed when a (loot is
installed. A louvered door with equivalent air
openings fi)r the fifll length of the (loot is
acceptable.
AIIowthe following clearances for ease of installation:
FRONT SIDES REAR TOP
Alcove O(Ocm) O(Ocm) O(Ocm) 15"(38.1cm)
Closet 1"(2.54cm) 0 (0cm) 0 (0cm) 15"(38.1cm)
Closet door ventilation required: 2 louvered
openings each 60 square inches (387.1 square cm)
--3" (7.6 cm) fi'om bottom and top of door.
0
I 1
Closet door
60 sq. in.
(387.1sq. cm)
_" "I cm)
0"(0cm)