21
Adequate voltage
to dryer?
Dryer Will Not Run
Electric Dryer
House fuse,
breaker, outlet
problem
N
Y
Repair terminal
block connection.
Door switch
contacts closed?
Y
Start switch
contacts closed?
Y
Timer contacts
B & C closed?
Y
Replace door
switch
Replace start
switch
N
Belt switch
contacts closed?
Y
Connections at
terminal block
OK?
Y
Replace timer
N
N
N
Replace belt
switch
Replace motor
Open wiring
between
components.
Locate and repair
N
N
Y
Y
N
Contacts on
thermal limiter
closed?
Replace thermal
limiter and
correct failure
fault
Check motor
centrifugal switch
reading between
contacts 4 & 5:
Or
Using a properly
grounded test
cord connected to
terminals 4 & 5
does the motor
run?
Adequate voltage
to dryer?
Gas Dryer
House fuse,
breaker, outlet
problem
N
Y
Replace door
switch
Start switch
contacts closing?
Timer contacts
B & C closed?
Y
Belt switch
contacts closed?
Y
Check motor
centrifugal switch
reading between
contacts 4 & 5:
Or
Using a properly
grounded test
cord connected to
terminals 4 & 5
does the motor
run?
Y
Replace start
switch
Replace timer
Replace belt
switch
N
Open wiring
between
components.
Locate and repair.
Y
Door switch
contacts closed?
Y
Replace motor
N
N
N
N