Installingthe dryer.
Read these instructions completely and carefully.
GroundingRequirements
__ DANGER:.,,properconnectionofthe
equipment-grounding conductor can result in
a risk of"electric shock. Check with a licensed
electrician if you are in doubt as m whether
the appliance is properly grounded.
Grounding must be in accordance with local
codes and ordinances, or in the absence of
local codes, in accordance with the National
Electrical Code %NSI/NFPA No. 70.
Fora grounded,cord-connectedelectricdryer.
[]The dryer MUSTbe grounded. In tile event of
a malfunction or breakdown, grounding will
reduce tile risk of electrical shock by creating
a path of least resistance for electrical current.
[] If your dryer is equipped with a power supply
cord having an equipment-grounding conductor
and a grounding plug, the plug MUSTbe
plugged into an appropriate, copper-wired
receptacle that is properly installed and
grounded in accordance with all local codes and
ordinances. Ifin doub_call alicensed electrician.
Fora permanently-connectedelectricdryer:
The dryer MUSTbe connected m a grounded
metal, permanent wiring system; or an equipment-
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal or lead on tile appliance.
Fora cord-connectedgas dryer:
This dryer is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly into
a properly grounded three-prong receptacle.
Do not cut or remove tile grounding prong from
this plug.
ElectricalInsta//ationfor ElectricDryers
__IL WARNING:The following are specific A WARNING.A UL-approved swain
requirements fbr proper and safe electrical relief must be installed onto power cord. K the
installation of your dryer. Failure to fbllow strain relief is not attached, tile cord can be pulled
these instructions can create electrical shock out of the dryer and can be cut by any movement of
and/or a fire hazard, tile cord, resulting in elecnical shock.
A WARNING:Thisappliance MUSTbe
properly grounded. Elecnical shock can result
if the dryer is not properly grounded. Follow
tile instructions in this manual for proper
grounding.
A WARNING:DONOTuseanextension
cord with this dryer. Some extension cords are
not designed to withstand the amounts of
electrical current this dryer utilizes and can
melt, creating electrical shock and/or fire
hazard. Locate the dryer within reach of tile
wall outlet, taking into account the length
of power cord to be purchased and allowing
some slack in tile cord. Refer m Electrical
Requirementsin this manual for the proper
power cord to be purchased.
A WARNING:u.co..errece.=desordv.
NOTE:Dryers operating on 208-volt power supply will
have longer drying times than those operating on
240-volt power supply.
A wiring diagram is located inside the control panel.