lnsta!lation Instructions
[] RECONNECTING GAS
NEWMETAL
FLEXIBLEGAS
LINECONNECTOR
ADAPTER
ITEMSNOTSUPPLIED
ELBOW
3/8"NPT
1/8"NPTPIPE
PLUGFOR
GAS
INLETPRESSURE
SHUT-OFF
VALVE
/
__ PIPESIZE
ATLEAST1/2"
APPLYPIPECOMPOUND
TOTHEADAPTERAND
DRYERGASINLET,
\
TIGHTENTHEFLEXIBLE
GASLINEUSINGTWO
ADJUSTABLEWRENCHES,
APPLYPIPECOMPOUND
TOALLMALETHREADS,
TIGHTENALLCONNECTIONS
USINGTWOADJUSTABLEWRENCHES,
DONOTOVERTORQUEGASCONNECTIONS!
[] LEAK TEST
[ _WARNING - NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE,
Check all connecti(uls [br leaks with soapy solution or e<l_livalent.
Apply soap solution Leak test solution must not contain
ammonia which could cause damage to the brass fittings. If
leaks are fi_und, close valve, retigllten tile joint, mid repeat the
soap test.