4. Reinstall the end caps by using non-petroleum based lubricant to lubricate the
O-ring inside the end cap. Reinstall the end cap on the membrane element by
first, aligning the stinger into the hole in the end cap and then turn the end
cap slowly clockwise, as you push it down into the membrane element
housing.
5. Reattach the housing clamp and tighten.
6. Next reconnect the permeate and concentrate lines.
The machine is ready for start-up.