Main Conduit Removal
Remove Upper Spray Arm to access 1/4 “ hex head screw
which secures top of Main Conduit (immediately behind
Upper Spray Arm)
Remove 2 - ¼” hex head screws to remove Mid Docking Cone
Remove 4 ¼” hex head screws to remove Conduit Plate.
Pull up on plate then pull plate off the conduit, notice the
conduit seal (must be re-installed to ensure proper seal
and operation).
Conduit can now be removed by unhooking from the heater