EasyManua.ls Logo

GE GFE29HSDASS

GE GFE29HSDASS
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
73
5/4/2012
¾ The 3-way valve is used to direct refrigerant flow.
¾ The valve has four different positions.
They are referred to by the letters ‘A, ‘B’, ‘C’ and ‘D’
A = Open to the Fresh Food and Freezer evaporators in series (refrigerant
flows through the fresh food evaporator and then into the freezer
evaporator). This is also called the (Home Position)
B = Open to the Freezer evaporator only
C = Open to both the Fresh Food and Freezer evaporators via the individual
capillary tubes (this position is not currently used on these models)
D = Closed to both Fresh Food and Freezer evaporators during the off cycle
3-Way Valve

Related product manuals