Pull Down
¾ Pull down occurs any time the refrigerator is plugged in and the freezer
temperature is above 60˚F*.
¾ The 3-way valve moves to the ‘B’ position. Compressor start is delayed for 20*
seconds. The compressor will start and run at high speed for 1 minute, then
change to low speed (variable speed models only). The freezer fan will run at
HIGH* speed.
¾ When the freezer temperature falls to approximately 12˚F*, the compressor will
change to HIGH* speed and the 3-way valve will move to the ‘Aposition,
delivering refrigerant to both the fresh food and freezer evaporators. The fresh
food fan will begin running at HIGH speed and the freezer fan will continue to
run at HIGH* speed.
¾ Compressor and fan speeds will vary with cabinet temperatures until the set
temperature is obtained.
¾ After 6* hours of compressor run time (door openings not counted), both the
fresh food and freezer will enter a heated defrost cycle.
* Values are approximate and preliminary