Installation Instructions
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUSTbe installed within
42 inches(107 cm)of your washers water inlet.The faucets
MUSTbe 3/4" (1.9cm) garden hose-type so inlet hosescan
be connected. Water pressure MUSTbe between 10 and 120
pounds per square inch.Your water department can advise
you of your water pressure.The hot water temperature
should be set to deliver water at 120° to 140°F(48°-60°C)
to provide proper Automatic Temperature Control (ATC)
performance.
NOTE:A water softener is recommended to reduce buildup of
scale inside the steam generator if the home water supply is
very hard.
DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals (64.3L)
per minute.
2. A standpipe diameter of Z Z/4" (3.!8 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 24" (61 cm)
Haximum height: 96" (244cm)
BACK
96" (8 ft,)
(244 cm)
Max.
24" (2 ft.)
(61 cm)
Min.
NOTE:The drain hoseattached to the washer can reach
a 58" (!47 cm) high standpipe. For a higher standpipe,
contact an authorized parts distributor.
INSTALLING THE WASHER
.
.
3.
.
Runsome water from the hot and cold faucets to flush the
water lines and remove particles that might clog the inlet
hose and water valve screens.
Removethe inlet hosesfrom the packaging.
(90°elbow end) Ensurethere is a rubber washer in the
90° elbow end of the HOT _:::o_:.................
and COLDhoses. Reinstall
the rubber washer into the ;,-- --__.__j
_L
hosefitting if it has fallen out
during shipment. Carefully
connect the inlet hose
marked HOTto the outside
"H" outlet of the water valve. ',_ib_
Tighten by hand, then tighten
another 2/3 turn with pliers.
Carefullyconnect the other inlet hose to the inside "C"outlet
of the water valve.Tighten by hand;then tighten another
2/3 turn with pliers.Do not crossthread or over-tighten
these connections.
If inlet hose screen washers are not already inserted into
the inlet hoses,install them by inserting into the free ends
of the HOTand COLDinlet hoseswith protruded side facing
the faucet.
__-_-h_,,rfleireHOS_/_
_Washers _
5. Connect the inlet hose ends to the HOTand COLD
water faucets tightly by hand, then tighten another _
2/3 turn with pliers.Turn the water on and check -J
for leaks.
6. Carefully move the washer to its final location. Gently rock
the washer into position. Itis important not to damage the
rubber leveling legswhen moving your washer to its final
location. Damaged legscan increasewasher vibration. It
may be helpful to spray window cleaner on the floor to help
move your washer into itsfinal position.
NOTE:To reducevibration, ensure that all four rubber
leveling legsare firmly touching the floor. Pushand pull
on the back right and then back left of your washer.
NOTE:Donot usethe dispenser drawer or door to lift
the washer.
NOTE:Ifyou are installing into a drain pan,you can use
a 24-inch long 2x4 to lever the washer into place.