Specification Created 3/15
GTD42GASJ
GE
®
Series 7.2 Cu. Ft. Capacity Gas Dryer
For answers to your Monogram
®
, GE Profile
Series
or GE
®
Series appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
Exhaust OptiOn: When viewed from the front of the
unit, exhaust 3-way via rear, left and bottom. Dryer is shipped
exhausted to the rear. Alternate exhausting knockouts
are supplied.
Gas: An individual, properly-grounded branch circuit, with
a three-prong grounding-type receptacle, protected by a 15
or 20 amp circuit breaker or a time-delay fuse is required.
Gas DryEr ElEctric ratinG: 120V, 60Hz, 6A
Gas (Btu/hr): 22,000. Factory-equipped for natural gas.
Tested for LP gas. LP gas supply requires a conversion kit.
Check installation instructions for correct kit and have a
qualified gas technician install a conversion kit. See dryer
ducting information for proper installation.
nOtE: Dryer wall outlet must be located within 36" of service
cord entry and accessible when dryer is mounted in position.
installatiOn infOrmatiOn: For complete information,
see installation instructions packed with your dryer.
DimEnsiOns anD installatiOn infOrmatiOn (in inchEs) spEcial installatiOn rEquirEmEnts
alcOvE Or clOsEt installatiOn:
- If your dryer is approved for installation in an alcove or closet, it will be stated
on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side; 3" front and rear
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
- Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet
with a gas dryer.
BathrOOm Or BEDrOOm installatiOn:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence
of local codes, with the National Electric Code and National Fuel Gas
Code, ANSI Z223 for gas dryers.
minimum clEarancEs OthEr than alcOvE Or clOsEt
installatiOn:
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DryEr ExhaustinG infOrmatiOn : Use metal duct only, vertical
and horizontal ducting.
Question and Answer IconNeed help?

Do you have a question about the GE GTD42GASJ and is the answer not in the manual?

GE GTD42GASJ Specifications

General IconGeneral
BrandGE
ModelGTD42GASJ
TypeGas Dryer
Capacity7.2 cu. ft.
Energy SourceGas
Voltage120V
ColorWhite
Drum MaterialAluminized Alloy
Number of Cycles12
Number of Temperature Settings4
Wrinkle Care OptionYes
Moisture SensorYes
Auto DryYes
End of Cycle SignalYes
Lint FilterYes
Reversible DoorYes
Weight120 lbs
Height44 in

Summary

DIMENSIONS AND INSTALLATION INFORMATION

EXHAUST OPTION

Details the 3-way exhaust options from the unit: rear, left, and bottom.

GAS

Specifies electrical requirements for gas dryers, including circuit protection.

GAS DRYER ELECTRIC RATING

Provides the electric rating (120V, 60Hz, 6A) for the gas dryer.

GAS (BTU/HR)

States the gas input rating (22,000 BTU/HR) and conversion for LP gas.

INSTALLATION INFORMATION

Refers to the complete installation instructions packed with the dryer.

POWER CORD LOCATIONS

Illustrates the locations where the power cord can be connected.

SPECIAL INSTALLATION REQUIREMENTS

ALCOVE OR CLOSET INSTALLATION

Details clearances and ventilation requirements for alcove or closet installations.

BATHROOM OR BEDROOM INSTALLATION

Specifies requirements for installations in bathrooms or bedrooms.

MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION

Outlines minimum clearances to combustible surfaces for non-alcove/closet installs.

DRYER EXHAUSTING INFORMATION

States that only metal ducting should be used for vertical and horizontal exhaust.

DUCTING AND VENTING

DUCTING MATERIALS

Recommends 4" rigid metal ducting, with UL-listed flexible metal as an alternative.

EXHAUST LENGTH CALCULATION

Provides guidance on calculating maximum vent length based on turns and duct type.

FEATURES AND BENEFITS

Auto Dry

Monitors air temperature for optimal drying time, ensuring great results.

Wrinkle Care

Reduces wrinkling and creasing through an extended tumble feature.

End-Of-Cycle Signal

Alerts users when the drying cycle is complete to prevent wrinkles.

4 heat selections

Offers four heat settings for various drying needs.

Up to 120 ft venting capability

Provides flexibility in installation with a long venting capacity.