Installation Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
MOBILE OR MANUFACTURED HOME
INSTALLATION
3
- Explosion Hazard
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
Installation must conform to the
MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24, PART 32–80 or
Standard CAN/CSA-Z240 MH, or, when such
standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened to a
non-combustible portion of the mobile home.
The vent MUST NOT be terminated beneath a
mobile or manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other
duct, vent or chimney.
Do not use sheet metal screws or other
fastening devices which extend into the interior
of the exhaust vent.
Provide an opening with a free area of at least
25 square inches for introduction of outside air
into the dryer room.
See the sections for electrical connection
information.
If the dryer is approved for installation in an
alcove or closet, it will be stated on a label on the
dryer back.
The dryer MUST be vented to the outdoors. See
the EXHAUSTING THE DRYER section.
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” either side
3” front
3” rear
Minimum vertical space from dryer to overhead
shelves, cabinets, ceilings, etc., is 1” on top.
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of
open area. If the closet contains both a washer
and a dryer, doors must contain a minimum of
120 square inches of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED IN
THE REAR OF THE DRYER, THE CONFIGURATION OF
THE DUCTING MAY REQUIRE GREATER THAN 3” OF
REAR CLEARANCE.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0” both sides, 1” front and
3” rear. Consideration must be given to provide
adequate clearance for installation and service.

Other manuals for GE GTD65EBPLDG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE GTD65EBPLDG and is the answer not in the manual?

GE GTD65EBPLDG Specifications

General IconGeneral
Colorwhite, diamond gray
Dryer Capactity7.4 cubic feet
Number of Cycles4
Cycle Selectionsanti-bacterial, towels and sheets, antibacterial, bulky items, damp dry, extended tumble, jeans, mixed load, my cycle, quick fluff, sanitize, towels/ sheets
Optionsextended tumble
Stackableno
Ventingtrue, vented
Temperature Settings5
Temperature Selectionshigh, medium, low, extra low, no heat
Temperature Controlyes
Delay Startyes
Child Lockno
Cycle Signalyes
Interior Lightyes
Drying Rackno
Moisture Sensor Optionyes
Steamno
Smart Homeno
Voltage240 volts
Current24 amperes
Weight and Dimensions IconWeight and Dimensions
Depth30 1/2 inches
Height46 inches
Width27 inches
Net Weight107 pounds