– 8 –
Product Specications
Specication for 15, 16 Cu Ft Mechanical Timer
Refrigerator
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING
DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation of
this information, nor can it assume any.
ELECTRICAL SPECIFICATIONS
Cold Control (Position 5) 28.0°F
Defrost Control @ 120 VAC
~60 Hz
15 hrs. / 33 min
Defrost Thermostat 64-23°F
Electrical Rating: 120 VAC AC 60Hz
Maximum Current Leakage 0.75 mA
Maximum Ground Path
Resistance
0.14 Ohms
NO LOAD PERFORMANCE
Control Position 5/C and Ambient
Temperature of 70°F 90°F
Fresh Food, °F / °C 33-39 33-41
Frozen Food, °F / °C (-4) -2 (-4) -4
Run Time % 23-33 37-49
REFRIGERATION SYSTEM
Refrigerant Charge
(R134a)
4.6 ounces / 0.13 kg
Compressor @ 120 VAC
~60 Hz
690 BTU/hr. / 202W
Minimum Vacuum @ 2
minutes
19 inches / 48 cm
Minimum Equalized Pressure
@70°F / 21°C 37.8 PSIG / 362 kPa
(abs)
@90°F / 32°C 50.7 PSIG / 451 kPa (abs
INSTALLATION
Clearance must be provided for air circulation
TOP 1 inch / 25 mm
SIDES 3/4 inch / 19 mm
REAR 2 inch / 51 mm
REPLACEMENTPARTS
Temperature Control WR09X21006
Defrost Control WR09X10049
Defrost Thermostat WR50X10071
Defrost Heater WR09X21107
Condenser Fan Motor WR60X20871
Evaporator Fan Motor WR60X10346
Relay/Overload WR08X10132
Drier WR86X0096
Fuse Harness WR55X21096
Pub. No. 31-51875-4