On electric models, the high limit thermostat 
is located on the top right area of the heater 
housing.  On gas models, the high limit 
thermostat is located on the upper right side of 
WKHGLႇXVHUDERYHWKHVDIHW\WKHUPRVWDW7KH
high limit thermostat monitors incoming air 
temperature.
If the thermostat reaches a temperature beyond 
its maximum temperature rating, it will trip and 
disable motor operation.
The high limit thermostat opens at 315°F. and will 
automatically reset at 250°F.
+LJK/LPLW7KHUPRVWDW5HPRYDO
1.  Remove the drum.  (See Drum in this section 
of this service guide.)
2.  Disconnect the two wires from the high limit 
thermostat. 
3.  Remove the Phillips-head screw that attaches 
the high limit thermostat to the heater 
DVVHPEO\RUGLႇXVHU
4.  Slide the thermostat from the heater assembly 
RUGLႇXVHU 
High Limit Thermostat
27-in. Electric 
Model 
24-in. Gas 
Model 
High Limit 
Thermostat
 Main Coil
Booster Coil
Safety Coil
The burner assembly has a gas valve that utilizes 
three coils.  A double coil (safety and booster 
coils combined) and a single main coil are located 
on top of the gas valve in front of the combustion 
chamber opening.  All coils can be replaced 
separately. 
Gas Valve Coil Assembly Resistance Values
Safety Coil Terminals: 1,400 :
 Booster Coil Terminals: 580 :
 Main Coil Terminals: 1,300 :
The burner assembly consists of the gas valve 
coils, gas valve, burner, and inlet pipe.
To convert the dryer from natural gas to LP gas, 
Refer to LP conversion kit (Part #: WE25x217).
 +LJK/LPLW7KHUPRVWDW   Burner Assembly and LP Conversion
  Gas Valve Coils