EasyManua.ls Logo

GE GUD27GSSMWW - Flame Detector; Ignitor

GE GUD27GSSMWW
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 39 –
7KHÀDPHGHWHFWRULVDWWDFKHGWRWKHULJKWVLGHRI
the combustion chamber.
Flame Detector Removal
1. Remove the drum. (See Drum in this section
of this service guide.)
2. 'LVFRQQHFWWKHWZRZLUHVIURPWKHÀDPH
detector.
3. Remove the Phillips-head screw that
KROGVWKHÀDPHGHWHFWRUWRWKHFRPEXVWLRQ
chamber.
4. 5HPRYHWKHÀDPHGHWHFWRUIURPWKHWDEDWWKH
bottom.
NOTE: Upon reassembly, ensure the tab at the
ERWWRPRIWKHÀDPHGHWHFWRULVLQVHUWHGLQWRWKH
slot located on the combustion chamber.
The ignitor is located at the end of the burner
assembly in the combustion chamber opening
and has a maximum rating of 4 amps. The ignitor
has an approximate resistance value of 40 to 400
ȍ
The ignitor is attached to the gas valve bracket
with a Phillips-head screw. To access the ignitor,
it is necessary to remove the burner assembly.
(See Gas Valve in this section of this service
guide, steps 1 through 10.)
Gas Valve Bracket
Flame
Detector
Flame Detector
,JQLWRU