11/16/2015
Drain And Recirculation Pump
Before removing the drain or
recirculation pump any water in the
basket must be removed. This is done by
using a transfer pump.
The transfer pump only comes with one
(1) hose. A standard washer hose can be
used for the outlet side of the pump. Part
number WH41X10207.
Pump out as much of the standing
water in the basket as possible.
Lean the washer back and pump out
the water seen in the basket.
When the drain pump is removed
approximately 12 cups of water will
drain out of the pump opening in the
tub.
Transfer Pump WX05X23817