EasyManuals Logo

GE Multilin 350 User Manual

GE Multilin 350
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
270
Distribution Feeder Protection
g
Digital Energy
Protection and Control
Phase, neutral and ground TOC and IOC
Undervoltage, overvoltage, frequency
Neutral/ground directional
Negative sequence Overcurrent
ANSI, IAC, IEC, flex curves
Cable Thermal Model Protection
Breaker Failure
Cold Load Pick Up
Four-shot auto-reclose
8 digital inputs, 7 contact outputs
Two setting groups
Metering & Monitoring
Event Recorder: 256 events
Oscillography with 32 samples per cycle
IRIG-B clock synchronization
Relay health diagnostics
Security audit trail
Metering - current, voltage, power, frequency
User Interface
• 4 line display for easy viewing of key data
• 10 LED indicators for quick diagnostics
• Front USB and rear RS485 serial communications
• Multiple Communication Protocols:
IEC 61850
IEC 61850 GOOSE,
MODBUS TCP/IP, MODBUS RTU,
DNP 3.0, IEC 60870-5-104, IEC 60870-5-103
EnerVista
TM
Software
EnerVista Software- an industry-leading suite of software
tools that simplifies every aspect of working with Multilin
devices.
Quick & easy configuration requiring minimal settings for
most feeder applications.
350
FEEDER PROTECTION SYSTEM
Intuitive and Innovative Feeder Protection
Multilin™
• Easy to use and intuitive overcurrent protection and control
for feeder applications.
• Effortless draw-out construction eliminates requirement for
test switches and reduces downtime
• Environmental monitoring system to alarm on destructive
operating conditions and plan preventative maintenance
• Easy to use interface and set up in one simple step
• Accelerated Life Cycle Tested to ensure reliability of relay
operation under abnormal conditions
• Advanced power system diagnostics to increase reliability
through fault and disturbance recording capabilities
• Flexible communications with multiple ports & protocols
to allow seamless integration into new and existing
infrastructure
• Arc flash mitigation via zone inter-tripping, flex curves, and
multiple settings group
• Powerful Security Audit Trail tool to increase security and
minimize system risks by tracking setting changes
• Application flexibility with the use of programmable logic
elements
Industrial feeders with enhanced breaker monitoring
diagnostics, etc.
Distribution utility down stream breaker protection
Medium voltage Utility feeders with advanced control features
Cold Load Pickup, auto reclose, multiple settings group, etc
FEATURES
APPLICATIONS
KEY BENEFITS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Multilin 350 and is the answer not in the manual?

GE Multilin 350 Specifications

General IconGeneral
BrandGE
ModelMultilin 350
CategoryRanges
LanguageEnglish

Related product manuals