EasyManua.ls Logo

GE Multilin 350 - Multilin 350 Feeder Protection System; Key Benefits; Applications; Features

GE Multilin 350
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
270
Distribution Feeder Protection
g
Digital Energy
Protection and Control
• Phase, neutral and ground TOC and IOC
• Undervoltage, overvoltage, frequency
• Neutral/ground directional
• Negative sequence Overcurrent
• ANSI, IAC, IEC, flex curves
• Cable Thermal Model Protection
• Breaker Failure
• Cold Load Pick Up
• Four-shot auto-reclose
• 8 digital inputs, 7 contact outputs
• Two setting groups
Metering & Monitoring
• Event Recorder: 256 events
• Oscillography with 32 samples per cycle
• IRIG-B clock synchronization
• Relay health diagnostics
• Security audit trail
• Metering - current, voltage, power, frequency
User Interface
• 4 line display for easy viewing of key data
• 10 LED indicators for quick diagnostics
• Front USB and rear RS485 serial communications
• Multiple Communication Protocols:
IEC 61850
IEC 61850 GOOSE,
MODBUS TCP/IP, MODBUS RTU,
DNP 3.0, IEC 60870-5-104, IEC 60870-5-103
EnerVista
TM
Software
• EnerVista Software- an industry-leading suite of software
tools that simplifies every aspect of working with Multilin
devices.
•
Quick & easy configuration requiring minimal settings for
most feeder applications.
350
FEEDER PROTECTION SYSTEM
Intuitive and Innovative Feeder Protection
Multilin™
• Easy to use and intuitive overcurrent protection and control
for feeder applications.
• Effortless draw-out construction eliminates requirement for
test switches and reduces downtime
• Environmental monitoring system to alarm on destructive
operating conditions and plan preventative maintenance
• Easy to use interface and set up in one simple step
• Accelerated Life Cycle Tested to ensure reliability of relay
operation under abnormal conditions
• Advanced power system diagnostics to increase reliability
through fault and disturbance recording capabilities
• Flexible communications with multiple ports & protocols
to allow seamless integration into new and existing
infrastructure
• Arc flash mitigation via zone inter-tripping, flex curves, and
multiple settings group
• Powerful Security Audit Trail tool to increase security and
minimize system risks by tracking setting changes
• Application flexibility with the use of programmable logic
elements
•
Industrial feeders with enhanced breaker monitoring
diagnostics, etc.
•
Distribution utility down stream breaker protection
• Medium voltage Utility feeders with advanced control features
Cold Load Pickup, auto reclose, multiple settings group, etc
FEATURES
APPLICATIONS