QUICK START GUIDE
MULTILINK ML1600/2400 ETHERNET COMMUNICATIONS SWITCH – QUICKSTART GUIDE QS–51
Z Enter the path to the folder in which the configuration file will be
stored
Z Select Xmodem as the receiving protocol.
Z Enter a name for the configuration file.
Z Click OK.
The configuration file will be stored at the specified location.
Z Verify that the configuration file has been created and stored
correctly.
This completes the Save (original) Configuration procedure.
The following procedure describes how to upgrade the firmware:
Z If the current firmware is older than 1.7.3, use the upgrade
command:
ML1600/2400# upgrade mode=serial
Do you wish to upgrade the image? [Y or N] Y
See figure below.
Z If the current firmware is older than 1.7.3, use the xmodem
command:
ML1600/2400# Xmodem get type=app